کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4055826 1603852 2016 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Validity and reliability of the activPAL3 for measuring posture and stepping in adults and young people
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Validity and reliability of the activPAL3 for measuring posture and stepping in adults and young people
چکیده انگلیسی


• The activPAL3 is valid for the detection of posture and purposeful stepping.
• Posture detection was excellent for standardised activities.
• Only purposeful steps during activities of daily living were detected by the monitor.
• The activPAL3 demonstrates good to excellent (ICC(1,1)) inter-device reliability.

Characterisation of free-living physical activity requires the use of validated and reliable monitors. This study reports an evaluation of the validity and reliability of the activPAL3 monitor for the detection of posture and stepping in both adults and young people. Twenty adults (median 27.6y; IQR22.6y) and 8 young people (12.0y; IQR4.1y) performed standardised activities and activities of daily living (ADL) incorporating sedentary, upright and stepping activity. Agreement, specificity and positive predictive value were calculated between activPAL3 outcomes and the gold-standard of video observation. Inter-device reliability was calculated between 4 monitors. Sedentary and upright times for standardised activities were within ±5% of video observation as was step count (excluding jogging) for both adults and young people. Jogging step detection accuracy reduced with increasing cadence >150 steps min−1. For ADLs, sensitivity to stepping was very low for adults (40.4%) but higher for young people (76.1%). Inter-device reliability was either good (ICC(1,1) > 0.75) or excellent (ICC(1,1) > 0.90) for all outcomes. An excellent level of detection of standardised postures was demonstrated by the activPAL3. Postures such as seat-perching, kneeling and crouching were misclassified when compared to video observation. The activPAL3 appeared to accurately detect ‘purposeful’ stepping during ADL, but detection of smaller stepping movements was poor. Small variations in outcomes between monitors indicated that differences in monitor placement or hardware may affect outcomes. In general, the detection of posture and purposeful stepping with the activPAL3 was excellent indicating that it is a suitable monitor for characterising free-living posture and purposeful stepping activity in healthy adults and young people.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Gait & Posture - Volume 43, January 2016, Pages 42–47
نویسندگان
, , , ,