کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4059815 1603869 2013 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Kinematic analysis following implantation of the PRESTIGE LP
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Kinematic analysis following implantation of the PRESTIGE LP
چکیده انگلیسی

BackgroundThe clinical success of cervical arthroplasty hinges on the ability to preserve or improve the biomechanics of the functional spinal unit. The purpose of this study was to conduct a radiologic assessment of kinematic parameters preimplantation and postimplantation of the PRESTIGE LP Cervical Disc System (Medtronic, Memphis, Tennessee).MethodsA total of 120 radiographs of 20 patients following single-level implantation of the PRESTIGE LP were retrospectively reviewed. Static and dynamic radiologic assessments were performed before surgery and at 1 year postoperation. Kinematic parameters including range of motion (ROM), horizontal translation, center of rotation (COR X, Y), anterior disc height and posterior disc height, and disc angle and shell angle were assessed for each spinal level using quantitative motion analysis software. Clinical outcomes were assessed using the short form health survey physical component scores and mental component scores.ResultsThe mean physical component scores and mental component scores of the short form health survey (SF-36) improved significantly following surgery. At 1 year postoperation, ROM, translation, and COR X were preserved. The COR Y shifted superiorly from 3.17 ± 2.08 mm preoperation to 0.98 ± 2.23 mm postoperation (P < .001). The anterior disc height and posterior disc height were significantly increased following surgery (3.97 ± 1.01 to 4.78 ± 1.11 mm and 3.04 ± 0.69 to 3.66 ± 0.61 mm, respectively; P < .01). The preoperative disc angle was 3.32° ± 2.92° and the postoperative shell angle was 1.11° ± 4.29°, with a mean change of −2.22° ± 4.63° (P < .05).ConclusionsThe PRESTIGE LP maintained preoperative ROM, translation, and COR X values. The postoperative COR Y value changed significantly by shifting superiorly, accompanied by an increase in DH. There was a loss of lordosis at the level of surgery, with the PRESTIGE LP endplates having an almost parallel endplate configuration.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The International Journal of Spine Surgery - Volume 7, Issue 1, December 2013, Pages e118–e122
نویسندگان
, , ,