کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4061190 1604034 2011 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Catastrophic Failure of a Metal-on-Metal Total Hip Arthroplasty Secondary to Metal Inlay Dissociation
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Catastrophic Failure of a Metal-on-Metal Total Hip Arthroplasty Secondary to Metal Inlay Dissociation
چکیده انگلیسی
Metal-on-metal bearing surfaces in total hip arthroplasty have been recently shown to have acceptable survivorship properties (J Bone Joint Surg Am. 2006;88:1183; J Bone Joint Surg Am. 2006;88:1173), and they have certain advantages and disadvantages when compared to conventional metal-on-polyethylene bearing surfaces. Like traditional metal-on-polyethylene bearings, these metal-on-metal implants may also suffer from catastrophic failure. This case report represents an unusual situation in a 57-year-old man in which dissociation of a metal inlay in a metal-on-metal total hip arthroplasty resulted in articulation of the inferior aspect of the inlay with the femoral neck, leading to femoral neck notching, extensive periprosthetic soft tissue metallosis, osteolysis, and subsequent prosthetic catastrophic failure.