To assess the validity and reliability of the mechanomyogram (MMG) as a tool to investigate the fatigue-induced changes in the muscle during relaxation, the torque and MMG signals from the gastrocnemius medialis muscle of 23 participants were recorded during tetanic electrically-elicited contractions before and immediately after fatigue, as well as at min 2 and 7 of recovery. The peak torque (pT), contraction time (CT) and relaxation time (RT), and the acceleration of force development (d2RFD) and relaxation (d2RFR) were calculated. The slope and τ of force relaxation were also determined. MMG peak-to-peak was assessed during contraction (MMG p–p) and relaxation (R-MMG p–p). After fatigue, pT, d2RFD, d2RFR, slope, MMG p–p and R-MMG p–p decreased significantly, while CT, RT and τ increased (P < 0.05 for all comparisons), remaining altered throughout the entire recovery period. R-MMG p–p correlated with pT, MMG p–p, slope, τ and d2RFR both before and after fatigue. Reliability measurements always ranged from high to very high. In conclusion, MMG may represent a valid and reliable index to monitor the fatigue-induced changes in muscle mechanical behavior, and could be therefore considered an effective alternative to the force signal, also during relaxation.
Journal: Journal of Electromyography and Kinesiology - Volume 23, Issue 6, December 2013, Pages 1295–1303