کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4071086 1604452 2007 14 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Resurfacing Arthroplasty Versus Silicone Arthroplasty for Proximal Interphalangeal Joint Osteoarthritis
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
پیش نمایش صفحه اول مقاله
Resurfacing Arthroplasty Versus Silicone Arthroplasty for Proximal Interphalangeal Joint Osteoarthritis
چکیده انگلیسی

PurposeTo compare the outcomes of silicone proximal interphalangeal joint (PIPJ) arthroplasties to pyrolytic carbon implants in patients with osteoarthritis.MethodsThis study is a retrospective review of 41 arthroplasties in 22 patients with severe PIPJ osteoarthritis performed by a single surgeon. There were 13 patients and 22 joints in the silicone group with an average follow-up of 45 months. There were 9 patients and 19 joints in the pyrolytic carbon group with an average follow-up of 19 months. Clinical assessment included range of motion, grip strength, and deformity. Radiographs were evaluated for alignment, subsidence, and implant fracture. Patients filled out a subjective questionnaire with respect to pain, appearance of the finger, and satisfaction. Complications were recorded.ResultsIn the silicone group, the average preoperative PIPJ range of motion (ROM) was 11°/64° (extension/flexion) and the average postoperative ROM was 13°/62°. In the pyrolytic carbon group, the average preoperative PIPJ ROM was 11°/63° and the average postoperative ROM was 13°/66°. Eleven of 20 joints in the silicone group and 4 of 19 joints in the pyrolytic carbon group had a coronal plane deformity as defined by angulation of the PIPJ ≥10°. The average coronal plane deformity was 12° in the silicone group and 2° in the pyrolytic carbon group. The difference was statistically significant. In the silicone group, 3 of 22 joints required additional surgery. Two implants in one patient were removed and the PIPJ fused, and one implant was permanently removed for sepsis. In the pyrolytic carbon group, 8 of 19 joints squeaked, and there were 2 early postoperative dislocations and 2 implants with radiographic loosening. To date, there has been no revision surgery. Both groups had good pain relief. Patients were generally satisfied with the appearance of their joints in the pyrolytic carbon arm; however, satisfaction with appearance was variable in the silicone group. Nine of 13 patients in the silicone group and 6 of 7 patients in the pyrolytic carbon group would have the procedure again.ConclusionsBoth implants provide excellent pain relief and comparable postoperative ROM. Complications were implant specific. The results of this series show promise for the pyrolytic carbon PIPJ resurfacing arthroplasty but did not clearly demonstrate superiority compared with the silicone implant.Type of study/level of evidenceTherapeutic III.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Journal of Hand Surgery - Volume 32, Issue 6, July–August 2007, Pages 775–788
نویسندگان
, , , ,