Mini C-arm image intensifiers are used commonly in surgery of the upper limb. With relatively low doses of emitted ionising radiation, portability and superior quality of image, they are a useful aid to the operating surgeon. However, these benefits are not so often used outside the theatre setting. This paper examines the use of a mini C-arm image intensifier in the out-patient clinic and presents an audit of 100 consecutive out-patients. We reviewed the potential benefits and effects on their care pathway. We also look at the specific radiation protection issues of the mini C-arm image intensifier in the out-patients clinic. We believe use of the mini C-arm image intensifier in the out-patient setting may speed treatment and reduce the cost of treatment.
Journal: The Journal of Hand Surgery: European Volume - Volume 32, Issue 5, October 2007, Pages 563–568