کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4096637 1268568 2014 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Reliability and measurement error of sagittal spinal motion parameters in 220 patients with chronic low back pain using a three-dimensional measurement device
ترجمه فارسی عنوان
پایایی و خطای اندازه گیری پارامترهای حرکتی نخاعی در 220 بیمار مبتلا به کمردرد مزمن با استفاده از دستگاه اندازه گیری سه بعدی
کلمات کلیدی
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
چکیده انگلیسی

Background contextA basic premise for any instrument measuring spinal motion is that reliable outcomes can be obtained on a relevant sample under standardized conditions.PurposeThe purpose of this study was to assess the overall reliability and measurement error of regional spinal sagittal plane motion in patients with chronic low back pain (LBP), and then to evaluate the influence of body mass index, examiner, gender, stability of pain, and pain distribution on reliability and measurement error.Study design/settingThis study comprises a test-retest design separated by 7 to 14 days.Patient sampleThe patient cohort consisted of 220 individuals with chronic LBP.Outcome measuresKinematics of the lumbar spine were sampled during standardized spinal extension-flexion testing using a 6-df instrumented spatial linkage system.MethodsTest-retest reliability and measurement error were evaluated using interclass correlation coefficients (ICC1,1) and Bland-Altman limits of agreement (LOAs).ResultsThe overall test-retest reliability (ICC1,1) for various motion parameters ranged from 0.51 to 0.70, and relatively wide LOAs were observed for all parameters. Reliability measures in patient subgroups (ICC1,1) ranged between 0.34 and 0.77. In general, greater (ICC1,1) coefficients and smaller LOAs were found in subgroups with patients examined by the same examiner, patients with a stable pain level, patients with a body mass index less than below 30 kg/m2, patients who were men, and patients in the Quebec Task Force classifications Group 1.ConclusionsThis study shows that sagittal plane kinematic data from patients with chronic LBP may be sufficiently reliable in measurements of groups of patients. However, because of the large LOAs, this test procedure appears unusable at the individual patient level. Furthermore, reliability and measurement error varies substantially among subgroups of patients.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Spine Journal - Volume 14, Issue 9, 1 September 2014, Pages 1835–1843
نویسندگان
, , , , ,