کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
4280446 | 1611559 | 2010 | 5 صفحه PDF | دانلود رایگان |

BackgroundThe purpose of this study was to determine the reliability of a previously validated laparoscopic Nissen fundoplication procedural checklist as a measurement of advanced technical skill.MethodsFive surgeons, using a 65-step procedural checklist, independently evaluated 2 video recordings of expert surgeon operative performances of a laparoscopic Nissen fundoplication. Results were analyzed for percent agreement and Fleiss kappa correlation for each operation independently and combined as a whole.ResultsSixty-four of the 65 steps had 80% or higher percent agreement for both operative case A and B independently and when considered overall. The Fleiss kappa coefficients for operative case A (kappa = .95) and operative case B (kappa = .96) and overall (operative case A + B) (kappa = .95).ConclusionThe percentage agreement and kappa coefficients for all 3 analyses indicate a high degree of reliability (>.80) that would support the use of this instrument for high-stakes assessment of a laparoscopic Nissen fundoplication.
Journal: The American Journal of Surgery - Volume 199, Issue 1, January 2010, Pages 110–114