کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4289460 1612109 2015 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Metal on metal total hip arthroplasty and a large groin mass: Not always adverse reaction to metallic debris
ترجمه فارسی عنوان
آرتروپلاستی لگن فلزی بر روی فلزی و جرم بزرگ کشاله ران: همیشه در معرض واکنش های بیرونی فلزی نیست
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی عمل جراحی
چکیده انگلیسی

Due to their improved wear rates, Metal-on-metal bearings have been increasingly used in the past decade by orthopaedic surgeons carrying out total hip arthroplasty. However there is increasing evidence that there are significant complications associated with such implants. One well documented complication is that of metallic debris leading to pseudotumour formation, however there is less known about associations with other tumours within the pelvis. We present two cases where an intra-pelvic mass in patients with metal-on-metal implants were diagnosed as being of a different aetiology. This highlights the need for careful assessment of such patients in order to guide appropriate management.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Surgery Case Reports - Volume 6, 2015, Pages 141–145