کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
4297440 | 1288321 | 2016 | 4 صفحه PDF | دانلود رایگان |
ObjectiveTo determine the effect of instrumentation of suture material on knot security and tensile strength.Study DesignIn all, 5 types of suture material were used; 10 knots were tied without any instrumentation and 10 knots were tied with a hemostat holding tension on the first throw while the second throw was made for each suture type. Each group was tested to failure with the maximum load and mode of failure recorded. The maximum load between groups of each suture type was compared; frequency of failure through knot slippage vs material fracture was also compared between groups.ResultsThere was no significant difference observed in the maximum load to failure for any suture type between instrumented and noninstrumented groups. Additionally, there was no difference between any instrumented and noninstrumented groups for material failure vs failure due to knot slippage.ConclusionsInstrumentation of suture material during two-hand tying does not affect the strength of suture material or knot security.
Journal: Journal of Surgical Education - Volume 73, Issue 1, January–February 2016, Pages 162–165