کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4365283 1301750 2011 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Microbiological induced corrosion of AA 6061 nuclear alloy in highly diluted media by Bacillus cereus RE 10
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم محیط زیست علوم زیست محیطی (عمومی)
پیش نمایش صفحه اول مقاله
Microbiological induced corrosion of AA 6061 nuclear alloy in highly diluted media by Bacillus cereus RE 10
چکیده انگلیسی

Microbiological studies of a spent nuclear fuel pool in Argentina were performed to evaluate the risk of microbiological induced corrosion and determine the cultivable bacterial population. Based on standard methods and sequencing of the 16sRNA gene, eighteen microorganisms were identified. Bacillus cereus RE 10 was the predominant organism isolated, and was selected to investigate the biofilm formation process and the corrosion effect on aluminum alloy AA 6061 and on pure aluminum (Al 99.999%). To simulate the environmental conditions, the experiments were performed using a highly diluted medium. After 20 days of exposure, major pits covered with deposits were found on AA 6061 samples exposed to B. cereus RE 10 but not on Al 99.999%. There was a close correlation between biofilm patches, corrosion deposits, pitting and Al–(Fe or Ti)–Si inclusions. We postulate that this correlation is a consequence of a light local alkalinization around the inclusions that produces changes in the expression pattern of B. cereus RE 10 and allows bacterial survival using other substrates. Under these conditions, the generated biofilm induces a crevice corrosion effect around the intermetallic inclusions of the alloy. Our results will be useful for further studies related to the microbial impact on nuclear safety in nuclear waste storage facilities in Argentina.


► Twenty microorganisms were identified from a spent nuclear fuel pool.
► Bacillus cereus was the predominant organism isolated.
► We examine Bacillus cereus corrosive effect on aluminum alloy 6061 in high diluted medium.
► Bacillus cereus induces under deposits corrosion only at Al–(Fe or Ti)–Si inclusions.
► This could be related to the local pH microenvironments around the inclusions.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Biodeterioration & Biodegradation - Volume 65, Issue 8, December 2011, Pages 1161–1168
نویسندگان
, , , ,