This paper describes the development and application of a multi-channel monitoring system for recording, processing, and analyzing volatile organic compound (VOC) levels discharged to the atmosphere from a walk-in hood in a hazardous waste management facility. The monitoring system consists of an array of PID (photo ionization detector) sensors and a networked control program that provides operational schematic diagram, performs data analyses, and illustrates real-time graphical displays. Furthermore, the system records potential worker exposures, exhaust filtration efficiency and environmental release levels. Multi-channel continuous monitoring of VOCs is successfully implemented during chemical bulking operations. It is shown that a real-time monitoring system is effective for early warning detection of hazardous chemicals and for predicting the performance of adsorption filters used for VOC removal. In addition, a connected local weather visualization system supports efforts to minimize potential health and environmental impacts of VOC emissions to surrounding areas.