کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
4453424 | 1312162 | 2006 | 8 صفحه PDF | دانلود رایگان |
![عکس صفحه اول مقاله: Characterization of a particle trap impactor Characterization of a particle trap impactor](/preview/png/4453424.png)
A particle trap impactor with a cup shaped collector was evaluated with varying geometrical and operating parameters. The acceleration nozzles having different diameters were designed, and the distance between the acceleration nozzle and the particle trap was changed. The aim of this work was to find out the accurate design parameters of particle trap impactors. Interestingly, our results indicated that Stk50 (i.e., Stk of a particle having a 50% probability of separation) of particle trap impactors were about 0.6, whereas those of inertial impactors and virtual impactors were 0.49 and 0.69, respectively. It is apparent that Stk50 values of particle trap impactors can be set at 0.6, even though their design conditions are somewhat different. In addition, the penetration efficiency was found to be dependent on the ratio of nozzle-to-trap distance to nozzle diameter, the sampling flow rate and the nozzle diameter.
Journal: Journal of Aerosol Science - Volume 37, Issue 8, August 2006, Pages 1016–1023