کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4547257 1627100 2009 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Validation of two innovative methods to measure contaminant mass flux in groundwater
موضوعات مرتبط
مهندسی و علوم پایه علوم زمین و سیارات فرآیندهای سطح زمین
پیش نمایش صفحه اول مقاله
Validation of two innovative methods to measure contaminant mass flux in groundwater
چکیده انگلیسی
Experiments in the artificial aquifer show that the TCW multi-dipole and tracer test techniques accurately estimated flux, within 2% and 16%, respectively; although the good results obtained using the multi-dipole technique may be fortuitous. The MIPT method was not as accurate as the TCW method, underestimating flux by as much as 70%. MIPT method inaccuracies may be due to the fact that the method assumptions (two-dimensional steady groundwater flow to fully-screened wells) were not well-approximated. While fluxes measured using the MIPT method were consistently underestimated, the method's simplicity and applicability to the field may compensate for the inaccuracies that were observed in this artificial aquifer test.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Contaminant Hydrology - Volume 106, Issues 1–2, 15 April 2009, Pages 51-61
نویسندگان
, , , , , , ,