کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
4920964 | 1429212 | 2017 | 8 صفحه PDF | دانلود رایگان |
Firebrands are a harbinger of damage to infrastructure; their effects cause a particularly important threat to people living within the wildland-urban-interface. Short-range firebrands travel with the wind with little or no lofting, and cause spotfires. In this work, the design of a novel firebrand generator prototype is discussed to achieve a uniform shower of firebrands. The transport of short-range firebrand is studied to verify the existing Lagrangian particle model of Fire Dynamics Simulator. Uniform, non-combusting cubiform and cylindrical firebrands are projected using the firebrand generator. The experimentally observed distribution of particles on the ground is compared with a simulated distribution using the fire dynamic simulator. The results show that the existing Lagrangian model gives a good agreement with the experimental data.
Journal: Fire Safety Journal - Volume 91, July 2017, Pages 776-783