کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4991730 1457117 2017 32 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Heat transfer characteristics and operation limit of pressurized hybrid heat pipe for small modular reactors
ترجمه فارسی عنوان
ویژگی های انتقال حرارت و محدودیت عملیاتی لوله گرم ترکیبی تحت فشار برای راکتورهای کوچک مدولار
کلمات کلیدی
لوله گرما ترکیبی محدودیت عملیات، ترموسفون حلقوی، لوله حرارتی، راکتور کوچک مدولار، سیستم ایمنی منفعل،
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
چکیده انگلیسی
In this paper, a hybrid heat pipe is proposed for use in advanced nuclear power plants as a passive heat transfer device. The hybrid heat pipe combines the functions of a heat pipe and a control rod to simultaneously remove the decay heat generated from the core and shutdown the reactor under accident conditions. Thus, the hybrid heat pipe contains a neutron absorber in the evaporator section, which corresponds to the core of the reactor pressure vessel. The presence of the neutron absorber material leads to differences in the heated diameter and hydraulic diameter of the heat pipe. The cross-sectional areas of the vapor paths through the evaporator, adiabatic, and condenser sections are also different. The hybrid heat pipe must operate in a high-temperature, high-pressure environment to remove the decay heat. In other words, the operating pressure must be higher than those of the commercially available thermosyphons. Hence, the thermal performances, including operation limit of the hybrid heat pipe, were experimentally studied in the operating pressure range of 0.2-20 bar. The operating pressure of the hybrid heat pipe was controlled by charging the non-condensable gas which is unused method to achieve the high saturation pressure in conventional thermosyphons. The effect of operating pressure on evaporation heat transfer was negligible, while condensation heat transfer was affected by the amount of non-condensable gas in the test section. The operation limit of the hybrid heat pipe increased with the operating pressure. Maximum heat removal capacity of the hybrid heat pipe was up to 6 kW which is meaningful value as a passive decay heat removal device in the nuclear power plants. Based on the experimentally measured maximum heat removal capacities, models predicting the operation limit (flooding limit) of the hybrid heat pipe were developed.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Thermal Engineering - Volume 112, 5 February 2017, Pages 560-571
نویسندگان
, ,