کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
4992789 1457394 2017 36 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Experimental investigation of thermal performance of metal foam wicked flat heat pipe
ترجمه فارسی عنوان
بررسی تجربی عملکرد حرارتی فوم فلزی لوله گرما تختخواب
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
چکیده انگلیسی
Experimental investigations of thermal performance of a flat heat pipe (FHP) with and without wick columns were investigated. Copper metal foam fabricated by lost carbonate sintering process and characterized by Scanning Electron Microscope (SEM) was used as wick structure. The effect of heat input, cooling water flow rate, cooling water temperature and fill ratio on the thermal response of the FHP is presented. Results showed that the heat transfer coefficient increases with increased Reynolds number and cooling water temperature but decreases with increased heat input and amount of fill ratio. It was found that increasing the wick volume by inserting additional wick columns improves the FHP performance, due to the decreased thermal resistance with increased fluid movement in these additional wick columns. The experimental results were compared with that of analytical calculations at steady state and a good agreement was observed between them.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Experimental Thermal and Fluid Science - Volume 82, April 2017, Pages 482-492
نویسندگان
, , ,