کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | ترجمه فارسی | نسخه تمام متن |
---|---|---|---|---|---|
4994279 | 1458034 | 2017 | 13 صفحه PDF | سفارش دهید | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Characteristics of steady and oscillating flows through regenerator
ترجمه فارسی عنوان
ویژگی های جریان ثابت و نوسان از طریق بازسازی کننده
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
سفارش ترجمه تخصصی
با تضمین قیمت و کیفیت
کلمات کلیدی
موتور بازسازی استرلینگ، جریان مداوم، نوسان جریان، اختلال،
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی شیمی
جریان سیال و فرایندهای انتقال
چکیده انگلیسی
Regenerator is one of heat exchangers (heater, regenerator and cooler) in a Stirling engine, whose flow characteristics are very important for developing Stirling engine design methodology. A combined experimental and simulation study is carried out to investigate characteristics of regenerator in an oscillating flow, using steady flow as reference. It is found that the oscillating flow can share the same correlation equations of steady flow for friction factor within the measured kinetic Reynolds number range (2.59Â ÃÂ 10â2-2.04Â ÃÂ 10â1 for 100Â mesh, 6.60Â ÃÂ 10â3-5.22Â ÃÂ 10â2 for 200Â mesh, 2.74Â ÃÂ 10â3-2.16Â ÃÂ 10â2 for 300Â mesh and 1.43Â ÃÂ 10â3-1.13Â ÃÂ 10â2 for 400Â mesh) and dimensionless fluid displacement, and the maximum deviation between the experimental data and simulation results is found less than 9.6%. It is also found that the effect of gas compression can't be ignored for the steady and oscillating flows through a regenerator with the increase of mass flow, and the pressure drop per unit length decreases as the length of regenerator increases. The velocities at both ends of regenerator are also affected by the compression of gas, and it is found that theoretical velocity based on piston velocity can be used if the dimensionless pressure drop of the whole system is less than 4.22Â ÃÂ 10â2 in this experiment. After all, it should be noted that oscillating flow has its own characteristics, and obvious flow perturbations are found at downstream of regenerator, which are exactly detected by a hot wire anemometer. The effect of mesh size, frequency and mean pressure on the perturbation is investigated, and a correlation equation for the duration of perturbation is proposed based on dimensionless pressure drop of regenerator.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Heat and Mass Transfer - Volume 108, Part A, May 2017, Pages 309-321
Journal: International Journal of Heat and Mass Transfer - Volume 108, Part A, May 2017, Pages 309-321
نویسندگان
Gang Xiao, Hao Peng, Haoting Fan, Umair Sultan, Mingjiang Ni,
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
سفارش ترجمه تخصصی
با تضمین قیمت و کیفیت