کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5031178 1470941 2017 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Sensitive fluorescent detection of DNA methyltransferase using nicking endonuclease-mediated multiple primers-like rolling circle amplification
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
پیش نمایش صفحه اول مقاله
Sensitive fluorescent detection of DNA methyltransferase using nicking endonuclease-mediated multiple primers-like rolling circle amplification
چکیده انگلیسی
Sensitive and reliable detection of DNA methyltransferase (MTase) is of great significance for both early tumor diagnosis and therapy. In this study, a simple, label-free and sensitive DNA MTase-sensing method was developed on the basis of a nicking endonuclease-mediated multiple primers-like rolling circle amplification (RCA) strategy. In this method, a dumbbell RCA template was prepared by blunt-end ligation of two molecules of hairpin DNA. In addition to the primer-binding sequence, the dumbbell template contained another three important parts: 5′-CCGG-3′ sequences in double-stranded stems, nicking endonuclease recognition sites and C-rich sequences in single-stranded loops. The introduction of 5′-CCGG-3′ sequences allows the dumbbell template to be destroyed by the restriction endonuclease, HpaII, but is not destroyed in the presence of the target MTase-M.SssI MTase. The introduction of nicking endonuclease recognition sites makes the M.SssI MTase-protected dumbbell template-mediated RCA proceed in a multiple primers-like exponential mode, thus providing the RCA with high amplification efficiency. The introduction of C-rich sequences may promote the folding of amplification products into a G-quadruplex structure, which is specifically recognized by the commercially available fluorescent probe thioflavin T. Improved RCA amplification efficiency and specific fluorescent recognition of RCA products provide the M.SssI MTase-sensing platform with high sensitivity. When a dumbbell template containing four nicking endonuclease sites is used, highly specific M.SssI MTase activity detection can be achieved in the range of 0.008-50 U/mL with a detection limit as low as 0.0011 U/mL. Simple experimental operation and mix-and-detection fluorescent sensing mode ensures that M.SssI MTase quantitation works well in a real-time RCA mode, thus further simplifying the sensing performance and making high throughput detection possible. The proposed MTase-sensing strategy was also demonstrated to be applicable for screening and evaluating the inhibitory activity of MTase inhibitors.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 91, 15 May 2017, Pages 417-423
نویسندگان
, , , , , , ,