کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5031323 1470933 2018 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Fully disposable microfluidic electrochemical device for detection of estrogen receptor alpha breast cancer biomarker
ترجمه فارسی عنوان
دستگاه الکتروشیمیایی میکرو فلوئیدیک کاملا یکبار مصرف برای شناسایی بیومارکرهای سرطان پستان آلفا گیرنده استروژن
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آنالیزی یا شیمی تجزیه
چکیده انگلیسی


- An innovative and cost-effective fully disposable microfluidic device is proposed.
- Highly decorated magnetic particles and protein-DNA interaction was used for cancer biomarker detection.
- Ultrasensitive breast cancer biomarker detection in undiluted calf serum.
- Microfluidic electrochemical array device allows simultaneous protein detection.

A novel fully disposable microfluidic electrochemical array device (µFED) was developed and successfully applied for detection of the biomarker estrogen receptor alpha (ERα). The µFED was constructed using low-cost materials and an inexpensive home cutter printer enabled the manufacture of dozens of µFEDs in less than 2 h, at a cost of less than US$ 0.20 in material per device. The µFED incorporates counter and reference electrodes and eight carbon-based working electrodes, which were modified with DNA sequences known as estrogen response elements (DNA-ERE), where ERα binds specifically. Paramagnetic particles heavily decorated with anti-ERα antibody and horseradish peroxidase (MP-Ab-HRP) were used to efficiently capture ERα from the sample solution. The ERα-MP-Ab-HRP bioconjugate formed was injected into the µFED and incubated with the DNA-ERE-modified electrodes, followed by amperometric detection with application of −0.2 V vs. Ag|AgCl while a mixture of H2O2 and hydroquinone was injected into the microfluidic device. An ultralow limit of detection of 10.0 fg mL−1 was obtained with the proposed method. The performance of the assay, in terms of sensitivity and reproducibility, was studied using undiluted calf serum, and excellent recoveries in the range of 94.7-108% were achieved for the detection of ERα in MCF-7 cell lysate. The µFED system can be easily constructed and applied for multiplex biomarker detection, making the device an excellent cost-effective alternative for cancer diagnosis, especially in developing countries.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Biosensors and Bioelectronics - Volume 99, 15 January 2018, Pages 156-162
نویسندگان
, , , , ,