Study of Glow Wire Ignition Temperature (GWIT) and Comparative Tracking Index (CTI) performances of engineering thermoplastics and correlation with material properties
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آلی
پیش نمایش صفحه اول مقاله
Study of Glow Wire Ignition Temperature (GWIT) and Comparative Tracking Index (CTI) performances of engineering thermoplastics and correlation with material properties
چکیده انگلیسی

Recent regulation IEC 60335-1 ed.4 (2008) was introduced for materials used in electric appliance, establishing new limits in Glow Wire Ignition Temperature (GWIT) performance for materials used for electric connectors. Development of new products with high GWIT is possible, but the main issue is to keep good mechanical properties and processability, as well as tracking resistance (Comparative Tracking Index-CTI). Only a few patents and scientific publications exist about glow wire test performance of polymers. In this work we report GWIT and CTI properties for three engineering thermoplastic polymers (PBT, PET and PC). We have also studied the phenomena involved in this test, treating the phenomena with the parameterisation approach already used in the studies of the fire behaviour of polymers. PC, PBT and PET filled with 30% w/w glass fibres have been tested, and material properties that can be related to GWIT and CTI performance have been measured by TGA, Laser Flash Thermal Diffusivity (LFTD), Pyrolysis-GC/MS. CTI seems to be correlated with the char formation tendency of the materials, so PBT show a higher tracking resistance than PET and PC. Polycarbonate was the only material that passed the glow wire test (GWIT higher than 775 °C) but generally GWIT performance is not directly related with degradation temperature, since PET is thermally more stable compared with PBT, but less stable in glow wire test. The ignition process, together with the unsteady heat and mass transfer process characteristic of glow wire testing, are affected by many parameters at the same time. That's why it is not easy to relate results of TGA, Laser flash, Pyrolysis-GC/MS with the glow wire ignition temperature of the materials tested, but the whole of these properties can give useful indication.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Polymer Degradation and Stability - Volume 96, Issue 4, April 2011, Pages 566-573
نویسندگان
, , , , ,