کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5207470 1382352 2006 10 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Test MethodComparison of permeability determined by permeation cell and immersion methods for organic solvents through protective gloves
موضوعات مرتبط
مهندسی و علوم پایه شیمی شیمی آلی
پیش نمایش صفحه اول مقاله
Test MethodComparison of permeability determined by permeation cell and immersion methods for organic solvents through protective gloves
چکیده انگلیسی

The chemical resistance of protective gloves has been tested using the ASTM F739 standard permeation method, as well as the immersion gravimetric method. Diffusion and solubility coefficients of four organic solvents, benzene, toluene, ethyl benzene and p-xylene, in nitrile and neoprene gloves were investigated. The diffusion coefficients determined by the ASTM F739 method were consistent with the immersion test (r2=0.714, p=0.008), and their permeation coefficients showed excellent correlation (r2=0.979, p=0.011) for nitrile gloves. Using a one-dimensional diffusion equation based on Fick's second law, the simulation results indicated that the immersion test could be inappropriate for determining the diffusion and solubility coefficients of organic solvent permeation through neoprene gloves. For the practical purpose of effective evaluation, a test should be conducted to obtain the permeability using ASTM F739 method which can closely simulate the exposure conditions of workers wearing protective gloves.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Polymer Testing - Volume 25, Issue 7, October 2006, Pages 975-984