کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5480878 1522093 2017 53 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Experimental performance assessment of a vacuum cooling system through exergy analysis method
ترجمه فارسی عنوان
ارزیابی عملکرد تجربی سیستم خنک کننده خلاء با استفاده از روش آنالیز اگزرژی
موضوعات مرتبط
مهندسی و علوم پایه مهندسی انرژی انرژی های تجدید پذیر، توسعه پایدار و محیط زیست
چکیده انگلیسی
The food industry, especially the cooling of the food, is a major consumer of energy. The high energy consumption forces the food cooling industry for new refrigeration systems and cooling foods with the low energy consumption. Vacuum cooling method is fast and an evaporative process while it has many advantages such as shorter processing times, improved product shelf life, consequent energy savings, safety and quality. In the open literature, there is no study that has investigated exergy analysis, exergetic efficiency and Coefficient of Performance (COP) of vacuum cooling to the best of the authors' knowledge. The performance of the vacuum cooling system using mushroom (Agaricus Bisporus) is determined through these metrics. The results have indicated that the COP value of the vacuum cooling reaches 12 and the exergy efficiency is maximum 80 percent for 23.9 °C. Both the exergetic efficiency and COP values for the vacuum cooling are achieved at the lowest pressure. The variations of energy and exergy of evaporation and the exergy rate of the product for the vacuum cooling are also given.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Cleaner Production - Volume 161, 10 September 2017, Pages 781-791
نویسندگان
, ,