کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5522001 1545663 2017 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Research paperA biotin-drug extraction and acid dissociation (BEAD) procedure to eliminate matrix and drug interference in a protein complex anti-drug antibody (ADA) isotype specific assay
موضوعات مرتبط
علوم زیستی و بیوفناوری بیوشیمی، ژنتیک و زیست شناسی مولکولی بیوتکنولوژی یا زیست‌فناوری
پیش نمایش صفحه اول مقاله
Research paperA biotin-drug extraction and acid dissociation (BEAD) procedure to eliminate matrix and drug interference in a protein complex anti-drug antibody (ADA) isotype specific assay
چکیده انگلیسی


- Matrix interference was encountered during ADA development with traditional platforms.
- BEAD pre-treatment followed by an ECL semi-homogenous direct assay was developed.
- The BEAD pre-treatment was effective for ADA extraction, and removal of matrix interference.
- BEAD pre-treatment significantly enhanced ADA assay sensitivity and drug tolerance.

Monitoring anti-drug antibody (ADA) responses in patients receiving protein therapeutics treatment is an important safety assessment for regulatory agencies, drug manufacturers, clinicians and patients. Recombinant human IGF-1/IGFBP-3 (rhIGF-1/rhIGFBP-3) is a 1:1 formulation of naturally occurring protein complex. The individual IGF-1 and IGFBP-3 proteins have multiple binding partners in serum matrix with high binding affinity to each other, which presents challenges in ADA assay development. We have developed a biotin-drug extraction with acid dissociation (BEAD) procedure followed by an electrochemiluminescence (ECL) direct assay to overcome matrix and drug interference. The method utilizes two step acid dissociation and excess biotin-drug to extract total ADA, which are further captured by soluble biotin-drug and detected in an ECL semi-homogeneous direct assay format. The pre-treatment method effectively eliminates interference by serum matrix and free drug, and enhances assay sensitivity. The assays passed acceptance criteria for all validation parameters, and have been used for clinical sample Ab testing. This method principle exemplifies a new approach for anti-isotype ADA assays, and could be an effective strategy for neutralizing antibody (NAb), pharmacokinetic (PK) and biomarker analysis in need of overcoming interference factors.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Immunological Methods - Volume 446, July 2017, Pages 30-36
نویسندگان
, , , , ,