کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5627621 1406351 2017 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Focused high-resolution sonography of the suprascapular nerve: A simple surrogate marker for neuralgic amyotrophy?
ترجمه فارسی عنوان
سونوگرافی با وضوح بالا از عصب سوپراپاپولار: یک علامت جایگزین ساده برای آمیوتروفی عصبی
موضوعات مرتبط
علوم زیستی و بیوفناوری علم عصب شناسی عصب شناسی
چکیده انگلیسی


- Sonography of the suprascapular nerve can serve as a surrogate marker for neuralgic amyotrophy.
- Patients with neuralgic amyotrophy showed swelling of the suprascapular nerve on the affected side.
- This examination algorithm is simple and can substantiate the suspicion of neuralgic amyotrophy.

ObjectivesTo define the diagnostic value of high-resolution ultrasound (HRUS) of the suprascapular nerve (SSN) in the diagnosis of neuralgic amyotrophy (NA).MethodsThe cross-section areas (CSA) of the SSN at the C5 root (CSA1) and the omohyoid muscle in the midclavicular line (CSA2) were assessed bilaterally in 15 healthy volunteers and 14 patients with clinically and electrophysiologically verified NA.Receiver-operator-characteristics (ROC) curves were generated and cut-off values, sensitivity, specificity, positive (PPV) and negative predictive values (NPV), likelihood (LR) and odds ratios (OR) were calculated.ResultsPatients with NA had significantly higher CSA2-values than controls (6.36 ± 2.75 vs. 2.79 ± 0.83 mm2, p < 0.0001) and significantly higher ratios of SSN CSA2-values of the affected vs. contralateral side (224.6 ± 78.5% vs. 127.7 ± 51.1%, p < 0.0001). The ratios of SSN CSA2-values vs. CSA1-values (146.7 ± 74.5% vs. 99.9 ± 28.3%, p = 0.008) and CSA1-values were also significantly higher (4.70 ± 2.00 vs. 2.90 ± 0.90 mm2, p = 0.0028) than in controls.Beyond a CSA2 cut-off value of 4.2 mm2, the ROC-AUC was 0.939 [0.861-1.00] when compared against healthy volunteers and 0.971 [0.901-1.00] when compared to patients with degenerative shoulder pain. Sensitivity was 85.7% [57.2-98.2%], specificity 96.7% [82.8-99.9%], PPV 92.3% [64.0-99.8%], NPV 93.5% [78.6-99.2%], OR 174.0 [14.4-2106.0] and LR 25.7 (95% confidence intervals in brackets).ConclusionSSN swelling in the lateral cervical region could be a supportive finding to identify NA patients.SignificanceThis method allows for the rapid sonographic identification of NA.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Clinical Neurophysiology - Volume 128, Issue 8, August 2017, Pages 1438-1444
نویسندگان
, , , , ,