کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5668155 1592341 2016 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Performance evaluation of a rapid molecular diagnostic, MultiCode based, sample-to-answer assay for the simultaneous detection of Influenza A, B and respiratory syncytial viruses
موضوعات مرتبط
علوم زیستی و بیوفناوری ایمنی شناسی و میکروب شناسی میکروبیولوژی و بیوتکنولوژی کاربردی
پیش نمایش صفحه اول مقاله
Performance evaluation of a rapid molecular diagnostic, MultiCode based, sample-to-answer assay for the simultaneous detection of Influenza A, B and respiratory syncytial viruses
چکیده انگلیسی


- ARIES FluA/B and RSV assay is an easy-to-use molecular point of impact assay.
- Clinical sensitivity and specificity is comparable to laboratory developed assays.
- Clinical sensitivity is significantly better than that of DFA and ICT rapid tests.
- Pre-treatment of viscous samples is recommended for ARIES.

BackgroundClinical signs and symptoms of different airway pathogens are generally indistinguishable, making laboratory tests essential for clinical decisions regarding isolation and antiviral therapy. Immunochromatographic tests (ICT) and direct immunofluorescence assays (DFA) have lower sensitivities and specificities than molecular assays, but have the advantage of quick turnaround times and ease-of-use.ObjectiveTo evaluate the performance of a rapid molecular assay, ARIES FluA/B & RSV, using laboratory developed RT-PCR assays (LDA), ICT (BinaxNOW) and DFA.MethodsAnalytical and clinical performance were evaluated in a retrospective study arm (stored respiratory samples obtained between 2006-2015) and a prospective study arm (unselected fresh clinical samples obtained between December 2015 and March 2016 tested in parallel with LDAs).ResultsGenotype inclusivity and analytical specificity was 100%. However, ARIES was 0.5 log, 1-2logs and 2.5logs less sensitive for fluA, RSV and fluB respectively, compared to LDA. In total, 447 clinical samples were included, of which 15.4% tested positive for fluA, 9.2% for fluB and 26.0% for RSV, in both LDA and ARIES. ARIES clinical sensitivity compared to LDA was 98.6% (fluA), 93.3% (fluB) and 95.1% (RSV). Clinical specificity was 100% for all targets. ARIES detected 10.6% (4 fluA, 8 fluB, 11 RSV) and 26.9% (7 fluA, 3 fluB, 22 RSV) more samples compared to DFA and ICT, all confirmed by LDA.ConclusionAlthough analytically ARIES is less sensitive than LDA, the clinical performance of the assay in our tertiary care setting was comparable, and significantly better than that of the established rapid assays.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Clinical Virology - Volume 85, December 2016, Pages 65-70
نویسندگان
, , , , , ,