کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5751560 1619706 2017 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Spatial and temporal variation of particulate matter characteristics within office buildings - The OFFICAIR study
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم محیط زیست شیمی زیست محیطی
پیش نمایش صفحه اول مقاله
Spatial and temporal variation of particulate matter characteristics within office buildings - The OFFICAIR study
چکیده انگلیسی


- PM characteristics varied markedly among the European office buildings.
- One order of magnitude difference was observed for the PNC and the OP metrics.
- Spatial variation within a building is less significant than temporal variation.
- Trace element concentrations showed the largest variation within a building.
- Differences within a building might be more relevant in long term than short term.

In the frame of the OFFICAIR project, office buildings were investigated across Europe to assess how the office workers are exposed to different particulate matter (PM) characteristics (i.e. PM2.5 mass concentration, particulate oxidative potential (OP) based on ascorbate and reduced glutathione depletion, trace element concentration and total particle number concentration (PNC)) within the buildings. Two offices per building were investigated during the working hours (5 consecutive days; 8 h per day) in two campaigns.Differences were observed for all parameters across the office buildings. Our results indicate that the monitoring of the PM2.5 mass concentration in different offices within a building might not reflect the spatial variation of the health relevant PM characteristics such as particulate OP or the concentration of certain trace elements (e.g., Cu, Fe), since larger differences were apparent within a building for these parameters compared to that obtained for the PM2.5 mass concentration in many cases. The temporal variation was larger for almost all PM characteristics (except for the concentration of Mn) than the spatial differences within the office buildings. These findings indicate that repeated or long-term monitoring campaigns are necessary to have information about the temporal variation of the PM characteristics. However, spatial variation in exposure levels within an office building may cause substantial differences in total exposure in the long term. We did not find strong associations between the investigated indoor activities such as printing or windows opening and the PNC values. This might be caused by the large number of factors affecting PNC indoors and outdoors.

592

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Science of The Total Environment - Volumes 587–588, 1 June 2017, Pages 59-67