کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
5768083 1413213 2017 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Simultaneous determination of aspartame, cyclamate, saccharin and acesulfame-K in powder tabletop sweeteners by FT-Raman spectroscopy associated with the multivariate calibration: PLS, iPLS and siPLS models were compared
موضوعات مرتبط
علوم زیستی و بیوفناوری علوم کشاورزی و بیولوژیک دانش تغذیه
پیش نمایش صفحه اول مقاله
Simultaneous determination of aspartame, cyclamate, saccharin and acesulfame-K in powder tabletop sweeteners by FT-Raman spectroscopy associated with the multivariate calibration: PLS, iPLS and siPLS models were compared
چکیده انگلیسی


- The main artificial sweeteners were determined in powder tabletop sweeteners.
- Liquid chromatography-tandem mass spectrometry was used as reference technique.
- Raman spectroscopy was used as proposed analytical technique.
- Chemometrics analysis by PLS, iPLS and siPLS was used to build prediction models.
- DFT was used to calculate the frequencies to assign the spectral regions selected.

For the first time, a procedure for simultaneous determination of the main artificial sweeteners, aspartame (ASP), cyclamate (CYC), saccharin (SAC), and acesulfame-K (ACSK) by a spectroscopic method associated with the multivariate calibration is proposed. These analytes were quantified in tabletop sweeteners samples using FT-Raman spectroscopy. Liquid chromatography-tandem mass spectrometry (LC-MS/MS) was used as reference method. Partial least squares (PLS), interval PLS (iPLS), and synergism PLS (siPLS) methods were evaluated in a comparative study where the selected interval models presented better results. Multivariate regression models, such as PLS, iPLS and siPLS were built and the lower root mean square errors for prediction (RMSEP) found were 0.027-0.031% w/w, 0.316-0.363% w/w, 0.082-0.184% w/w, and 0.040-0.049% w/w to ASP, CYC, SAC, and ACSK, respectively. The coefficient of determination for prediction (R2p) varied between 0.978 and 0.979, 0.969-0.977, 0.952-0.994, and 0.959-0.965 for ASP, CYC, SAC and ACSK, respectively. The analysis of model's residues was made by bias and permutation tests to evaluate systematic and trend errors. The selected intervals by iPLS and siPLS were evaluated and the bands related to the vibrational modes of the analytes were assigned with the aid of density functional theory calculations (DFT).

98

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Food Research International - Volume 99, Part 1, September 2017, Pages 106-114
نویسندگان
, , , , , , , ,