عنوان انگلیسی مقاله ISI
A reinvestigation of EXAFS and EPR spectroscopic measurements of chromium(VI) reduction by coir pith
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
مهندسی و علوم پایه
مهندسی شیمی
بهداشت و امنیت شیمی
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
New measurements using extended X-ray absorption fine structure (EXAFS) and electron paramagnetic resonance (EPR) techniques are consistent with Cr in the Cr(III) oxidation state as the main product from the adsorption of Cr(VI) on coir pith. These confirm the previous X-ray measurements, but differ from the results of previous EPR studies, which indicated that Cr(V) was the main form of Cr. The reason for this discrepancy is the presence of a broad signal from Cr(III) in an unsymmetrical environment that was missed previously; the Cr(V) component is in fact only a minor reaction product. As a result of this problem with spectral acquisition and interpretation, some simple recommendations are presented for conducting EPR investigations on natural systems.