MIKE 3 versus HARTMANN apparatus: Comparison of measured minimum ignition energy (MIE)
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی بهداشت و امنیت شیمی
پیش نمایش صفحه اول مقاله
MIKE 3 versus HARTMANN apparatus: Comparison of measured minimum ignition energy (MIE)
چکیده انگلیسی
Nevertheless, ignition of a dust cloud by an electrostatic discharge is complex, and implies a different mechanism from that occurring during MIE tests. Thus, it seems difficult to synchronise dust dispersion and spark triggering to obtain optimal concentration in the spark area. Moreover, spark characteristics such as duration or energy feeding rate of spark cannot reproduce exactly industrial-world ones. On this point, it is not possible to conclude if characteristics of MIKE 3 electric circuit, e.g., resistance and inductance, are more relevant than HARTMANN circuit ones.