کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6001164 1182945 2015 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Regular ArticleEstablishing a reference range for thrombin generation using a standard plasma significantly improves assay precision
ترجمه فارسی عنوان
مقررات منظم ایجاد یک محدوده مرجع برای تولید ترومبین با استفاده از پلاسمای استاندارد به طور قابل توجهی دقت سنجش را بهبود می بخشد
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
چکیده انگلیسی


- Normalisation of thrombin generation data reduces inter-assay variability
- A standard plasma provides an internal quality control for thrombin generation data
- Accuracy of thrombin generation data is improved using an internal quality control
- Reference range for a standard plasma in thrombin generation assays established
- Progress in the standardization of thrombin generation techniques

BackgroundThrombin generation is a global coagulation assay which appears to be an effective method for assessing the potential for an individual's plasma to coagulate. However for this assay to become accepted in routine clinical practice it requires standardization.ObjectivesTo establish a reference range for the NIBSC reference plasma (TGT-RP) which can then become an internal quality control (IQC) for thrombin generation assays.Patients/MethodsThrombin generation was measured in TGT-RP in 153 independent experiments using 4 assay conditions; 1 pM tissue factor (TF) or 5 pM TF +/− thrombomodulin (TM). A target value +/− 2 SD was calculated to provide an acceptance range under the 4 conditions. A plasma sample from a healthy volunteer was subsequently tested in 11 separate experiments using the TGT-RP for (i) normalisation and (ii) exclusion of experimental results when the TGT-RP results did not fall within the established acceptance range.ResultsAn acceptance range was established for TGT-RP for the 4 assay conditions. Normalisation of all results from a healthy volunteer reduced inter-assay variability significantly (ETP: p = 0.0003; Peak: p = 0.001). Exclusion of results from the volunteer when concurrently run TGT-RP results fell outside the acceptance range reduced inter-assay variability significantly when reporting raw data (ETP: p = 0.001; Peak: p = 0.004). However normalisation of this data had no beneficial effect (ETP: p = 0.126; Peak: p = 0.232).ConclusionsOur work represents further progress in the standardization of thrombin generation techniques with the establishment of an IQC reference range. Using an IQC reduces inter-assay variability, whilst allowing reporting of raw data and ensures production of accurate and reproducible data.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Thrombosis Research - Volume 136, Issue 1, July 2015, Pages 139-143
نویسندگان
, ,