کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6001172 1182945 2015 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
From laboratory to clinical practice: Dabigatran effects on thrombin generation and coagulation in patient samples
ترجمه فارسی عنوان
از آزمایشگاه به عمل بالینی: اثرات دایتگراتان بر تولید ترومبین و انعقاد در نمونه های بیمار
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی کاردیولوژی و پزشکی قلب و عروق
چکیده انگلیسی


- Dabigatran is not routinely monitored, yet assessment is required in emergencies
- Thrombin specific tests measure dabigatran accurately as confirmed by LC-MS/MS
- Coagulation time based assays are less accurate but provide additional information
- Dabigatran paradoxically enhances thrombin generation in unselected patient samples
- The cause for enhanced thrombin generation is yet to be determined

IntroductionDabigatran (Dabi) is not routinely monitored. However, in emergency cases quantitative assessment is required and laboratories must provide suitable tests at all hours. Little is known about Dabi effects on thrombin generation.Materials and methodsPatient samples (n = 241) were analyzed for functional Dabi concentrations (Dabi-TT) using a combination of the Hemoclot Thrombin Inhibitors assay (HTI®) and, for samples with low levels, undiluted thrombin time (TT). Results were compared to prothrombin time (PT) and activated partial thromboplastin time (APTT). In 49 samples Dabi effects were further investigated with Calibrated Automated Thrombogram (CAT®) for thrombin generation and with Russell's viper venom time (RVVT), prothrombinase-induced clotting time (PiCT®), chromogenic Anti-IIa® and ecarin clotting assay (ECA®). Fibrinogen and D dimer were assessed to reflect the coagulation status of the patient. A subset of these samples (n = 21) were also analyzed by liquid chromatography-tandem mass spectrometry (LC-MS/MS).ResultsDabi-TT correlated with RVVT (R2 = 0.49), PiCT® (R2 = 0.73), ECA® (R2 = 0.89), Anti-IIa® (R2 = 0.90) and LC-MS/MS (R2 = 0.81). APTT correlated curvi-linearly with Dabi-TT (R2 = 0.71), but was normal in many cases (18/70) despite Dabi-TT > 40 ng/mL. There was no association between Dabi-TT and fibrinogen or D dimer levels. Increasing Dabi concentrations prolonged lag time (R2 = 0.54) and, surprisingly, elevated the ETP and Peak of CAT® (p < 0.001).ConclusionsThrombin-specific tests measure Dabi accurately, whereas coagulation time based assays depend more on other factors. The enhanced thrombin generation in Dabi-treated patients may predict clinically relevant hypercoagulability and warrants further investigation.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Thrombosis Research - Volume 136, Issue 1, July 2015, Pages 154-160
نویسندگان
, , , , , ,