کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6033478 1188747 2012 14 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Diffusion tractography of post-mortem human brains: Optimization and comparison of spin echo and steady-state free precession techniques
موضوعات مرتبط
علوم زیستی و بیوفناوری علم عصب شناسی علوم اعصاب شناختی
پیش نمایش صفحه اول مقاله
Diffusion tractography of post-mortem human brains: Optimization and comparison of spin echo and steady-state free precession techniques
چکیده انگلیسی

Diffusion imaging of post-mortem brains could provide valuable data for validation of diffusion tractography of white matter pathways. Long scans (e.g., overnight) may also enable high-resolution diffusion images for visualization of fine structures. However, alterations to post-mortem tissue (T2 and diffusion coefficient) present significant challenges to diffusion imaging with conventional diffusion-weighted spin echo (DW-SE) acquisitions, particularly for imaging human brains on clinical scanners. Diffusion-weighted steady-state free precession (DW-SSFP) has been proposed as an alternative acquisition technique to ameliorate this tradeoff in large-bore clinical scanners. In this study, both DWSE and DW-SSFP are optimized for use in fixed white matter on a clinical 3-Tesla scanner. Signal calculations predict superior performance from DW-SSFP across a broad range of protocols and conditions. DW-SE and DW-SSFP data in a whole, post-mortem human brain are compared for 6- and 12-hour scan durations. Tractography is performed in major projection, commissural and association tracts (corticospinal tract, corpus callosum, superior longitudinal fasciculus and cingulum bundle). The results demonstrate superior tract-tracing from DW-SSFP data, with 6-hour DW-SSFP data performing as well as or better than 12-hour DW-SE scans. These results suggest that DW-SSFP may be a preferred method for diffusion imaging of post-mortem human brains. The ability to estimate multiple fibers in imaging voxels is also demonstrated, again with greater success in DW-SSFP data.

► Comparison of DW-SE and DW-SSFP for post-mortem imaging on clinical scanners. ► Optimization of protocols predicts 50-130% higher SNR efficiency in DW-SSFP. ► Comparison of tractography 6- and 12-hour DW-SE and DW-SSFP scans. ► Lower uncertainty on fibre direction in DW-SSFP produces superior tractography. ► Crossing fibres can be estimated from 12-hour DW-SSFP data.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: NeuroImage - Volume 59, Issue 3, 1 February 2012, Pages 2284-2297
نویسندگان
, , , ,