کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
6039357 | 1188819 | 2008 | 8 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Reproducibility of fMRI in the clinical setting: Implications for trial designs
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
ROIEPIMNIEDSSPMd - PMDFunctional MRI - افامآرآی یا تصویرسازی تشدید مغناطیسی کارکردیfMRI - تصویرسازی تشدید مغناطیسی کارکردیfunctional magnetic resonance imaging - تصویرسازی تشدید مغناطیسی کارکردیDorsal premotor cortex - قشر پرموتور پشتیregion of interest - منطقه مورد نظرMontreal Neurological Institute - موسسه عصبی مونترالMultiple sclerosis - مولتیپل اسکلروزیس(ام اس)Plasticity - پلاستیکClinical trial - کارآزمایی بالینی
موضوعات مرتبط
علوم زیستی و بیوفناوری
علم عصب شناسی
علوم اعصاب شناختی
پیش نمایش صفحه اول مقاله

چکیده انگلیسی
With expanding potential clinical applications of functional magnetic resonance imaging (fMRI) it is important to test how reliable different measures of fMRI activation are between subjects and sessions and between centres. This study compared variability across 17 patients with multiple sclerosis (MS) and 22 age-matched healthy controls (HC) in 5 European centres performing an fMRI block design with hand tapping. We recruited subjects from sites using 1.5Â T scanners from different manufacturers. 5 healthy volunteers also were studied at each of 4 of the centres. We found that reproducibility between runs and sessions for single individuals was consistently much greater than between individuals. There was greater run-to-run variability for MS patients than for HC. Measurements of maximum signal change (MSC) appeared to provide higher reproducibility within individuals and greater sensitivity to differences between individuals than region of interest (ROI) suprathreshold voxel counts. The variability in measurements between centres was not as great as that between individuals. Consistent with these observations, we estimated that power should not be reduced substantially with use of multi-, as opposed to single-, centre study designs with similar numbers of subjects. Multi-centre interventional studies in which fMRI is used as an outcome measure thus appear practical even when implemented in conventional clinical environments.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: NeuroImage - Volume 42, Issue 2, 15 August 2008, Pages 603-610
Journal: NeuroImage - Volume 42, Issue 2, 15 August 2008, Pages 603-610
نویسندگان
R. Bosnell, C. Wegner, Z.T. Kincses, T. Korteweg, F. Agosta, O. Ciccarelli, N. De Stefano, A. Gass, J. Hirsch, H. Johansen-Berg, L. Kappos, F. Barkhof, L. Mancini, F. Manfredonia, S. Marino, D.H. Miller, X. Montalban, J. Palace, P.M. Matthews,