کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
6040106 | 1188834 | 2007 | 13 صفحه PDF | دانلود رایگان |
عنوان انگلیسی مقاله ISI
Balancing bias, reliability, noise properties and the need for parametric maps in quantitative ligand PET: [11C]diprenorphine test-retest data
دانلود مقاله + سفارش ترجمه
دانلود مقاله ISI انگلیسی
رایگان برای ایرانیان
کلمات کلیدی
موضوعات مرتبط
علوم زیستی و بیوفناوری
علم عصب شناسی
علوم اعصاب شناختی
پیش نمایش صفحه اول مقاله
![عکس صفحه اول مقاله: Balancing bias, reliability, noise properties and the need for parametric maps in quantitative ligand PET: [11C]diprenorphine test-retest data Balancing bias, reliability, noise properties and the need for parametric maps in quantitative ligand PET: [11C]diprenorphine test-retest data](/preview/png/6040106.png)
چکیده انگلیسی
[11C]diprenorphine (DPN) is a non-subtype selective opioid receptor PET ligand with slow kinetics and no region devoid of specific binding. Parametric maps are desirable but have to overcome high noise at the voxel level. We obtained parameter values, parametric map image quality, test-retest reproducibility and reliability (using intraclass correlation coefficients (ICCs)) for conventional spectral analysis and a derived method (rank shaping), compared them with values obtained through sampling of volumes of interest (VOIs) on the dynamic data sets and tested whether smaller amounts of radioactivity injected maintained reliability. Ten subjects were injected twice with either â¼Â 185 MBq or â¼Â 135 MBq of [11C]DPN, followed by dynamic PET for 90 min. Data were movement corrected with a frame-to-frame co-registration method. Arterial plasma input functions corrected for radiolabelled metabolites were created. There was no overall effect of movement correction except for one subject with substantial movement whose test-retest differences decreased by â¼Â 50%. Actual parametric values depended heavily on the cutoff for slow frequencies (between 0.0008 sâ 1 and 0.00063 sâ 1). Image quality was satisfactory for restricted base ranges when using conventional spectral analysis. The rank shaping method allowed maximising of this range but had similar bias. VOI-based methods had the widest dynamic range between regions. Average percentage test-retest differences were smallest for the parametric maps with restricted base ranges; similarly ICCs were highest for these (up to 0.86) but unacceptably low for VOI-derived VD estimates at the low doses of injected radioactivity (0.24/0.04). Our data can inform the choice of methodology for a given biological problem.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: NeuroImage - Volume 38, Issue 1, 15 October 2007, Pages 82-94
Journal: NeuroImage - Volume 38, Issue 1, 15 October 2007, Pages 82-94
نویسندگان
Alexander Hammers, Marie-Claude Asselin, Federico E. Turkheimer, Rainer Hinz, Safiye Osman, Gary Hotton, David J. Brooks, John S. Duncan, Matthias J. Koepp,