کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6196578 1602584 2015 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Photoacoustic tomography imaging and estimation of oxygen saturation of hemoglobin in ocular tissue of rabbits
ترجمه فارسی عنوان
تصویر برداری از توموگرافی عکس اتوفیزیک و برآورد اشباع اکسیژن هموگلوبین در بافت چشم های خرگوش
کلمات کلیدی
موضوعات مرتبط
علوم زیستی و بیوفناوری ایمنی شناسی و میکروب شناسی ایمونولوژی و میکروب شناسی (عمومی)
چکیده انگلیسی


- We used acoustic resolution (AR) photoacoustic tomography (PAT) and pulse oximetry.
- sO2 was measured in rabbit ciliary body tissue.
- AR PAT sO2 were lower than SPO sO2 values.
- Further studies are need to validate our initial results.

This study evaluated in vivo imaging capabilities and safety of qualitative monitoring of oxygen saturation of hemoglobin (sO2) of rabbit ciliary body tissues obtained with acoustic resolution (AR) photoacoustic tomography (PAT). AR PAT was used to collect trans-scleral images from ciliary body vasculature of seven New Zealand White rabbits. The PAT sO2 measurements were obtained under the following conditions: when systemic sO2 as measured by pulse oximetry was between 100% and 99% (level 1); systemic sO2 as measured by pulse oximetry was between 98% and 90% (level 2); and systemic sO2 as measured by pulse oximetry was less than 90% (level 3). Following imaging, histological analysis of ocular tissue was conducted to evaluate for possible structural damage caused by the AR PAT imaging.AR PAT was able to resolve anatomical structures of the anterior segment of the eye, viewed through the cornea or anterior sclera. Histological studies revealed no ocular damage. On average, sO2 values (%) obtained with AR PAT were lower than sO2 values obtained with pulse oximetry (all p < 0.001): 86.28 ± 4.16 versus 99.25 ± 0.28, 84.09 ± 1.81 vs. 95.3 ± 2.6, and 64.49 ± 7.27 vs. 71.15 ± 10.21 for levels 1, 2 and 3 respectively. AR PAT imaging modality is capable of qualitative monitoring for deep tissue sO2 in rabbits. Further studies are needed to validate and modify the AR PAT modality specifically for use in human eyes. Having a safe, non-invasive method of in vivo imaging of sO2 in the anterior segment is important to studies evaluating the role of oxidative damage, hypoxia and ischemia in pathogenesis of ocular diseases.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Experimental Eye Research - Volume 138, September 2015, Pages 153-158
نویسندگان
, , , , , , , , , ,