Clinical utility of ultrasound to prospectively monitor distraction of magnetically controlled growing rods
ترجمه فارسی عنوان
استفاده بالینی از سونوگرافی به طور چشمگیری مانع از انحراف از میله های رشد تحت کنترل مغناطیسی است
کلمات کلیدی
کنترل شده همبستگی، حواس پرتی، رو به رشد، مغناطیسی، راد، سونوگرافی،
موضوعات مرتبط
علوم پزشکی و سلامت پزشکی و دندانپزشکی ارتوپدی، پزشکی ورزشی و توانبخشی
چکیده انگلیسی

Background ContextGrowing rods are commonly used for surgical treatment of skeletally immature patients with scoliosis, but require repeated surgeries for distractions and are fraught with complications. As an alternative, the use of magnetically controlled growing rods (MCGR) allows for more frequent non-invasive distractions to mimic normal growth. However, more plain radiographs are needed to monitor increased distraction frequency, thereby increasing ionizing radiation exposure to the developing child. The use of ultrasound, which emits no radiation, has been found in a cross-sectional study to be reliable in measuring MCGR distractions.PurposeThe study aims to address the prospective clinical utility of ultrasound compared with plain radiographs for assessing MCGR distractions.Study DesignThis is a prospective study.Patient SampleThe study includes patients with early-onset scoliosis undergoing distractions after MCGR implant.Outcome MeasuresThe distraction length on plain radiographs and ultrasound was measured.MethodsThis is a prospective study of patients treated with MCGR. Patients with both single- and dual-rod systems were included. Outpatient distractions were performed at monthly intervals, targeting 2 mm of distraction on each occasion. Assessment of distraction length was monitored by ultrasound at each visit; plain radiographs were taken every 6 months and were compared with ultrasound measurements.ResultsNine patients (5 female, 4 male), with a mean of 29 distractions (standard deviation [SD] ±14.3), were recruited. The mean distracted length per 6 months was 5.7 mm (SD ±3.6 mm) on plain radiographs and 5.2 mm (SD ±3.9 mm) on ultrasound for the concave rod, and 6.1 mm (SD ±3.6 mm) on plain radiographs and 5.9 mm (SD ±3.8 mm) on ultrasound for the convex rod. Excellent inter- and intra-rater reliabilities were observed for radiographic and ultrasound measurements. An excellent correlation was noted between the two imaging modalities (r=0.93; p<.0001).ConclusionsThis is the first prospective study to validate that ultrasound assessment of MCGR distraction lengths was highly comparable with that of plain radiographs. The present study has verified that ultrasound can be used to document length changes by distraction over time and that it had high clinical utility. Ultrasound can be a reliable alternative to plain radiographs, thereby avoiding radiation exposure and its potential detrimental sequelae in the developing child.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: The Spine Journal - Volume 16, Issue 2, February 2016, Pages 204-209
نویسندگان
, , , , , , , , , , , , , ,