On reducing false alarms in multivariate statistical process control
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی تصفیه و جداسازی
پیش نمایش صفحه اول مقاله
On reducing false alarms in multivariate statistical process control
چکیده انگلیسی

The primary objective of this note is to reduce the false alarms in multivariate statistical process control (MSPC). The issue of false alarms is inherent within MSPC as a result of the definition of control limits. It has been observed that under normal operating conditions, the occurrence of “out-of-control” data, i.e. false alarms, conforms to a Bernoulli distribution. Therefore, this issue can be formally addressed by developing a Binomial distribution for the number of “out-of-control” data points within a given time window, and a second-level control limit can be established to reduce the false alarms. This statistical approach is further extended to consider the combination of multiple control charts. The proposed methodology is demonstrated through its application to the monitoring of a benchmark simulated chemical process, and it is observed to effectively reduce the false alarms whilst retaining the capability of detecting process faults.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Chemical Engineering Research and Design - Volume 88, Issue 4, April 2010, Pages 430–436