کد مقاله | کد نشریه | سال انتشار | مقاله انگلیسی | نسخه تمام متن |
---|---|---|---|---|
6254454 | 1288445 | 2012 | 6 صفحه PDF | دانلود رایگان |

BackgroundRecognition of different anatomic structures might be difficult in the presence of diseases such as neoplasm or endometriosis that can subvert the anatomy. This can be a challenge for young surgeons approaching gynecologic surgery. The aim of the present study was to evaluate the effectiveness of infrared thermocamera to identify the anatomic structures in gynecologic surgery.Materials and methodsFrom February 2010 to May 2011, consecutive patients who required abdominal hysterectomy were considered for eligibility. During a procedure for benign disease, we evaluated the temperature difference between the ureter and infundibulopelvic vessel (experiment A). In patients with gynecologic cancer, the thermal gradient was determined between the iliac vessels and the ureter (experiment B).ResultsThe data from 21 patients were recorded, 12 for experiment A and 9 for experiment B. We found a statistically significant difference between the ureter and vessels in both experiments (31.675°C ± 0.673°C for the ureter and 33.332°C ± 0.828°C for the infundibulopelvic vessel, P < 0.0001; 31.706°C ± 0.751°C for the ureter, 33.787°C ± 0.63°C for the iliac vein, and 33.784°C ± 0.639°C for the iliac artery, P < 0.0001).ConclusionsInfrared imaging allowed us to identify the anatomic structures in laparotomy, providing preliminary data for its application in laparoscopy.
Journal: Journal of Surgical Research - Volume 178, Issue 2, December 2012, Pages 539-544