کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6268859 1614643 2014 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Basic NeuroscienceValidation of an enzyme-linked immunoassay (ELISA) for plasma oxytocin in a novel mammal species reveals potential errors induced by sampling procedure
موضوعات مرتبط
علوم زیستی و بیوفناوری علم عصب شناسی علوم اعصاب (عمومی)
پیش نمایش صفحه اول مقاله
Basic NeuroscienceValidation of an enzyme-linked immunoassay (ELISA) for plasma oxytocin in a novel mammal species reveals potential errors induced by sampling procedure
چکیده انگلیسی


- An ELISA protocol for plasma oxytocin in phocid seals was validated.
- Sample handling protocols for accurately detecting plasma oxytocin were compared.
- Concentrations detected in raw plasma varied significantly with vacutainer type.
- Concentrations detected in extracted plasma were unaffected by vacutainer type.
- Capture and restraint protocol affected concentrations detected in raw plasma.

BackgroundThe neuropeptide oxytocin is increasingly the focus of many studies investigating human and animal social behaviours and diseases. However, interpretation and comparison of results is made difficult by a lack of consistent methodological approaches towards analysing this hormone.New methodThis study determined the sample collection and analysis protocols that cause the least amounts of protocol dependant variation in plasma oxytocin concentrations detected by ELISA. The effect of vacutainer type, sample extraction prior to analysis and capture and restraint protocol were investigated while validating an assay protocol for two novel species, grey seals (Halichoerus grypus) and harbour seals (Phoca vitulina).ResultsWhere samples are extracted prior to analysis, vacutainer type (EDTA mean: 8.25 ± 0.56 pg/ml, heparin mean: 8.25 ± 0.62 pg/ml, p = 0.82), time taken to obtain a sample and restraint protocol did not affect the concentration of oxytocin detected. However, concentrations of oxytocin detected in raw plasma samples were significantly higher than those in extracted samples, and varied significantly with vacutainer type (EDTA mean: 534.4 ± 43.7 pg/ml, heparin mean: 300.9 ± 19.6 pg/ml, p < 0.001) and capture and restraint methodology. There was no relationship between oxytocin concentrations detected in raw and extracted plasma (p = 0.25).Comparison with existing method(s)Over half the reviewed published studies analysing plasma oxytocin use raw plasma and different vacutainer types are used without consistency or justification through-out the literature.ConclusionsWe caution that studies using raw plasma are likely to over estimate oxytocin concentrations, cannot be used to accurately infer true values via correlations and are susceptible to variation according vacutainer type.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Journal of Neuroscience Methods - Volume 226, 15 April 2014, Pages 73-79
نویسندگان
, , , ,