کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
646270 884560 2014 8 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Testing of a lab-scale four-bed adsorption heat pump
ترجمه فارسی عنوان
آزمایش پمپ گرمایش جذب چهار لایه در آزمایشگاه
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
چکیده انگلیسی


• We tested the performance of a lab-scaled four-bed adsorption heat pump.
• A maximum SCP of 93 W/kg was found at cycle time of 11 min.
• A maximum COP of 0.55 was found at cycle time of 35 min.
• The liquid evaporation rate in the evaporator was much smaller than the vapor adsorption rate in the adsorber.

A lab-scale adsorption heat pump with four adsorbers was tested. The core structure of the adsorber is aluminum alloy finned tubes. Water was the adsorbate (refrigerant) and a fine silica gel granule was the adsorbent. At the regeneration temperature of 77.5 °C, a maximum SCP value of 93 W/kg silica gel was found. The corresponding optimum cycle time is 11 min and the COP value is 0.31. The COP value considerably increases with the cycle time. At the cycle time of 35 min, the COP value reaches a maximum of 0.54 and the corresponding SCP value is 73 W/kg silica gel. In the adsorption process, the evaporation rate of the liquid refrigerant in the evaporator was found to be much smaller than the vapor adsorption rate of the adsorbent in the adsorber. This resulted in a slow adsorption process and thus a descent of the maximum SCP value.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Thermal Engineering - Volume 70, Issue 1, 5 September 2014, Pages 274–281
نویسندگان
, ,