کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
646789 1457164 2013 6 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Performance analysis of heat storage of direct-contact heat exchanger with phase-change material
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Performance analysis of heat storage of direct-contact heat exchanger with phase-change material
چکیده انگلیسی
This paper describes the improvement of the heat-storage performance of a direct-contact heat exchanger using the phase-change material (PCM) erythritol (melting point: 391 K) and a heat transfer oil (HTO). A vertical cylinder with 200-mm inner diameter and 1400-mm height was used as the heat-storage unit (HSU). A nozzle pointing vertically downwards was placed on the bottom of the HSU. We examined the effect of the height of the PCM in HSU on heat storage, using two characteristic parameters: temperature effectiveness and the rate of heat storage. According to the results, both of these parameters increase during the increase in latent heat storage with the height of PCM, due to the increase in the residence time with the height of PCM.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Thermal Engineering - Volume 58, Issues 1–2, September 2013, Pages 108-113
نویسندگان
, , , , ,