کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
6473462 1424953 2018 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Parametric study on fouling mechanism and heat transfer characteristics of tube bundle heat exchangers for reducing fouling considering the deposition and removal mechanisms
ترجمه فارسی عنوان
بررسی پارامتریک مکانیزم آسیب رساندن و انتقال حرارت انتقال مبدل های حرارتی بسته بندی لوله برای کاهش فساد با توجه به مکانیزم رسوب گذاری و حذف
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی مهندسی شیمی (عمومی)
چکیده انگلیسی


- Fouling and heat transfer characteristics of a typical heat exchanger are investigated.
- A multiple mean cycle method is proposed based on a comprehensive fouling model.
- The effects of geometric parameters are discussed.
- The staggered elliptical tube is proposed to reduce the fly-ash fouling.

Particulate fouling on flue gas heat exchanger surfaces reduces heat transfer efficiency and increases the instability of equipment operation. It is necessary to develop a better understanding of how fouling occurs, aiming to find strategies to predict and reduce it. In this paper, a multiple mean cycle method is proposed based on a comprehensive fouling model considering the deposition and removal mechanisms, combined with the discrete phase model and dynamic mesh method, to predict the fouling morphology. Then the effects of transverse pitch, longitudinal pitch, tube shape and arrangement on fly-ash fouling and heat transfer characteristics are examined. It is found that, for aligned arrangement, the fly-ash particles are mainly deposited at the upwind stagnation region at the first row and whole windward side of the rest rows; for staggered arrangement, the fly-ash particles are deposited at the upwind stagnation region. The multiple mean cycle method can predict the fouling morphology efficiently and keep the characteristic of non-uniform fouling distribution. The fouling mass increases with the increase of relative transverse and longitudinal pitches. The elliptical tube bundle with small relative transverse and longitudinal pitches can obviously reduce the fouling mass especially for the staggered elliptical tube. Compared with the aligned circular tube arrangement, the fouling mass mf is decreased by 81.1% at 10 min. In addition, the weaken degree of Nusselt number after fouling ΔNu for the staggered elliptical tube is only about 49.8% of the aligned circular tube arrangement. Consequently, using the staggered elliptical tube contributes to reduce the fly-ash fouling, decrease the soot-blowing frequency and ensure the efficiency, economy and safety of flue gas heat exchangers.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Fuel - Volume 211, 1 January 2018, Pages 301-311
نویسندگان
, , , ,