کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
647508 1457179 2012 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Experimental study on an inverter heat pump with HFC125 operating near the refrigerant critical point
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Experimental study on an inverter heat pump with HFC125 operating near the refrigerant critical point
چکیده انگلیسی

An experimental study on an inverter heat pump with HFC125 operating near the refrigerant critical point was carried out. The coefficient of performance (COP) and exergy efficiency of the system were investigated under different compressor speed, water flow rate and different hot water temperatures of the condenser. The exergy defect in each component was determined. The results show that the exergy efficiency of the system increases initially and then decreases while the COP constantly decreases with the increase of the temperature of hot water. The results of this study can provide useful guidelines for optimal design and operation of this type of heat pump system in its present or future applications.

Figure optionsDownload as PowerPoint slideHighlights
► An inverter heat pump with HFC125 operating near the refrigerant critical point.
► The COP and exergy efficiency varied with outlet temperatures of heat sink.
► The exergy defect in each component was performed.
► A maximum exergy efficiency was obtained around 65 °C of hot water temperature.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Thermal Engineering - Volume 39, June 2012, Pages 1–7
نویسندگان
, , , ,