کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
648392 884621 2009 5 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Experimental study on the performance of an aircraft environmental control system
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Experimental study on the performance of an aircraft environmental control system
چکیده انگلیسی
In this paper, the experimental study on the off-design performance and dynamic response of an aircraft environmental control system (ECS) was presented. A bootstrap air cycle refrigeration system with high-pressure water separation was employed in the ECS. Both the static test and the dynamic test were conducted on the ECS. The performance of the key components including precooler, recuperator, compressor, and turbine was investigated. The test results show the performance of the tested ECS can meet the requirements of design. However, some parameters including outlet pressure, turbine efficiency, and rotational speed might vary obviously when the operation conditions changed. The outlet humidity ratio and outlet temperature might also fluctuate largely during the start-up process. It is necessary to take into account the off-design performance and the transient performance in the design of ECS.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Thermal Engineering - Volume 29, Issue 16, November 2009, Pages 3284-3288