کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
649019 1457212 2007 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Two-dimensional numerical simulation and performance analysis of tapered pulse tube refrigerator
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Two-dimensional numerical simulation and performance analysis of tapered pulse tube refrigerator
چکیده انگلیسی

Numerical simulation of two-dimensional viscous compressible oscillating flow was carried out for the uniform cross-section and tapered pulse tubes. Based on the numerical results, it was found that for the taper pulse tube refrigerator, there was an optimum taper angle, with which the performance of a cryogenic refrigerator can be greatly improved. However, on the other hand, the results also demonstrated that when the taper angle becomes much larger than this optimum value, the cooling performance becomes weaker than that of the circular tube. We discussed the effect of the tapered pulse tube on the performance of pulse tube refrigerator based on an evaluation of the secondary flow in the pulse tube. It was found that in comparison with the uniform cross-section pulse tube, the magnitude of the secondary flow in the tapered pulse tube decreases while its distribution becomes less uniform, which explains why the performance of the tapered pulse tube can be improved compared with the uniform cross-section pulse tube.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Thermal Engineering - Volume 27, Issues 11–12, August 2007, Pages 1876–1882
نویسندگان
, , , ,