کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
649203 884647 2009 9 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Performance of a residential heat pump operating in the cooling mode with single faults imposed
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Performance of a residential heat pump operating in the cooling mode with single faults imposed
چکیده انگلیسی

The system behavior of a R410A residential unitary split heat pump operating in the cooling mode was investigated. Seven artificial faults were implemented: compressor/reversing valve leakage, improper outdoor air flow, improper indoor air flow, liquid line restriction, refrigerant undercharge, refrigerant overcharge, and presence of non-condensable gas in the refrigerant. This study monitored eight fault detection features and identified the most sensitive features for each fault. The effect of the various fault levels on energy efficiency ratio (EER) was also estimated. Since the studied system employed a thermostatic expansion valve (TXV) as an expansion device, it could adapt to some faults making the fault less detectable. The distinctiveness of the fault depended on the TXV status (fully open or not).

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Thermal Engineering - Volume 29, Issue 4, March 2009, Pages 770–778
نویسندگان
, , , , ,