کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
649707 1457216 2006 7 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
First and second law analysis of pulse tube refrigerator
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
First and second law analysis of pulse tube refrigerator
چکیده انگلیسی

The first and second law of thermodynamics was used to analyze the orifice type and the double-inlet type of pulse tube refrigerator (PTR). Detailed dynamic characteristics of the thermodynamics, flow and heat transfer processes in the PTR were revealed, including the dynamic pressure variations, transient gas temperature, mass flow rate in the PTR. The exergy loss method was used to analyze each component in the PTR for the first time, and the performance coefficients of all components of PTR have been obtained. It was found that the performance coefficient of the double-inlet PTR was 0.108, 9% higher than that of the orifice PTR. The analysis also showed that the exergy efficiency of the double-inlet PTR was 29.95%, significantly higher than that of the orifice PTR (25.04%). In addition, it was found that the exergy losses in the regenerator and orifice were substantially larger than in other components of the PTR system. The optimal design of these two key components is, therefore, essential for the further improvement of the PTR performance.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Applied Thermal Engineering - Volume 26, Issues 17–18, December 2006, Pages 2301–2307
نویسندگان
, , , ,