کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
652046 884999 2011 11 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Thermo-hydraulic characterization of a louvered fin and flat tube heat exchanger
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Thermo-hydraulic characterization of a louvered fin and flat tube heat exchanger
چکیده انگلیسی
In the present study, a whole heat exchanger with a hydraulic diameter of 2.3 mm is tested, which is a minichannel heat exchanger according to the Kandlikar classification. This is a louvered fin and flat tube heat exchanger currently used in car cooling systems, also known as radiator. A glycol-water mixture (60/40 in volume) circulates through the tubes at flows ranging from 100 to 7800 l/h and at a supply temperature of 90 °C. This fluid is cooled with ambient air at a temperature of 20 °C and at frontal air velocities varying between 0.5 and 7 m/s. The thermohydraulic performance of the heat exchanger is compared with the classical correlations given in the literature for the heat transfer and the friction factor calculation. On the glycol-water side the heat exchanger is characterized for Reynolds numbers from 30 to 8000. A first comparison is carried out with the correlations available in the literature with a purely predictive model by obtaining a predictive value with a systematic under prediction lower than 10%. In a second step a semi-empirical model is considered to identify the experimental heat transfer coefficients for this application.
ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: Experimental Thermal and Fluid Science - Volume 35, Issue 1, January 2011, Pages 154-164
نویسندگان
, , , ,