کد مقاله کد نشریه سال انتشار مقاله انگلیسی نسخه تمام متن
662982 1458154 2007 13 صفحه PDF دانلود رایگان
عنوان انگلیسی مقاله ISI
Second law analysis of counter flow cryogenic heat exchangers in presence of ambient heat-in-leak and longitudinal conduction through wall
موضوعات مرتبط
مهندسی و علوم پایه مهندسی شیمی جریان سیال و فرایندهای انتقال
پیش نمایش صفحه اول مقاله
Second law analysis of counter flow cryogenic heat exchangers in presence of ambient heat-in-leak and longitudinal conduction through wall
چکیده انگلیسی

Performance of highly effective heat exchangers is governed by the various internal and external irreversibilities. In low temperature applications, the performance of these heat exchangers strongly depends on the irreversibilities such as ambient heat-in-leaks, longitudinal heat conduction through separating wall of heat exchanger and conduction through high temperature connecting tubes when they are integrated to the system. The special focus of present analysis is the study of effect of these irreversibilities on the performance of heat exchangers through second law analysis. It is observed that the effect of ambient heat-in-leak is different for the balanced and imbalanced counter flow high NTU heat exchangers. Study also makes it possible to compare the different irreversibilities for varying range of NTU and analyze the influence of external irreversibilities on the performance of heat exchangers when either hot fluid or cold fluid is minimum capacity fluid.

ناشر
Database: Elsevier - ScienceDirect (ساینس دایرکت)
Journal: International Journal of Heat and Mass Transfer - Volume 50, Issues 23–24, November 2007, Pages 4754–4766
نویسندگان
, , ,